F<sub>nenn</sub> = 500 N
&tau;<sub>IzulI</sub> = 200 N/mm<sup>2</sup> (Hartlote lt.Tab. 5.3 Roloff/Matek)
K<sub>A</sub> = 1 (Betriebsfaktor lt. Tab. 3.5 Roloff/Matek)
&tau;<sub>Izul</sub> =(K<sub>a</sub> * F) / A<sub>I</sub>
A<sub>I</sub> = (K<sub>a</sub> * F) / &tau;<sub>I</sub>
Berechnung der druckbeaufschlagten FlächeA<sub>I</sub> = (1 * 500N) / 200N/mm<sup>2</sup>
A = (d<supsub>2I</supsub> * &pi;) / 4=
A = (54<sup>2</sup>mm² * &pi;) / 4
A = <u>2.290,22 mm<sup>2</sup></u>
 
 
p<sub>e</sub> = F / A
 
F = p<sub>e</sub> * A
 
F = 0,8 N/mm<sup>2</sup> &middot; 2,29 &middot; 10<sup>3 </sup> mm<sup>2</sup>
 
F = <u>1,83 kN</u>
 
 
Berechnung der Lötnahtfläche
 
A<sub>I</sub> = d * &pi; * I<sub>ü</sub>
 
A<sub>I</sub> = 54 mm * &pi; * 10 mm
 
A<sub>I</sub> = <u>1.696,46 mm<sup>2</sup></u>
 
 
&tau;<sub>I</sub> =(K<sub>a</sub> * F) / A<sub>I</sub>
 
&tau;<sub>I</sub> =(1 * 1.832,17 N) / 1.696,46 mm
 
&tau;<sub>I</sub> = <u>1,08 N/mm<sup>2</sup></u>
 
 
S = &tau;<sub>Izul</sub> / &tau;<sub>I</sub>
 
S = 2N/mm<sup>2</sup> / 1,08N/mm<sup>2</sup>
 
S = <u>1,8</u>
Antwort:
Die Spaltlötverbindung hält der Belastung von 8 bar mit 1,8-facher Sicherheit stand!
Änderungen – BS-Wiki: Wissen teilen

Änderungen

720
Bearbeitungen